Level 1 gave you the foundation. Level 2 goes inside the drive itself: how the board builds AC for the compressor out of a DC bus, how it shapes that output, and why the switches get hot. Six on-demand lessons you take in order. Each part builds on the last, and you unlock the next part by passing the quiz.
Part 1: How an Inverter Makes AC (~21 min). The H-bridge and its three output voltages, harmonics and why they cost you heat and noise, the 30-degree trick, and how dead time and freewheeling diodes prevent shoot-through.
Part 2: Shaping the Pulses for a Cleaner Sine Wave (~18 min). Half-wave symmetry, the angle delta, harmonic elimination, harmonic cancellation, interleaving, and why your meter can fool you on a drive output.
Part 3: Pulse Width Modulation (PWM) (~23 min). Multilevel inverters, duty cycle, sine-triangle PWM, carrier frequency trade-offs, EMI and current control.
Part 4: Three-Phase Rectifiers (~21 min). The six-diode bridge, 6-pulse DC and ripple, what DC bus voltage to expect, line harmonics, power factor, reactors and 12- and 18-pulse designs.
Part 5: Three-Phase Inverters (~18 min). The six-switch bridge, switching states, the floating neutral, six-step and PWM, modulation index, and how to measure the inverter the right way.
Part 6: Switching Losses and Snubbers (~21 min). Conduction and switching loss, voltage spikes, the safe operating area, what snubbers do, and why most overheat problems come back to heat flow.
Included: on-demand video lessons you take at your own pace, a technician handout for every part, a quiz for every part (80% to pass), and one certificate of completion when you finish Level 2.
Price: $19.99 for all six parts of Level 2.
Taught by Don Gillis, Gillis Coach. Want this training brought to your location? Visit gilliscoach.com.